Narda Safety Test Solutions S.r.l. Leader on Electromagnetic Compatibility and EMC EMI Receiver  
   English  Italiano
PMM a Brand of Narda Safety Test Solutions S.r.l. Electromagnetic Compatibility EMC EMI Instruments
 
 
  Receivers

Narda offers a full range of FULL and PRE compliance receivers, even with FFT technology, covering the range 10 Hz - 18 GHz. As a small size, flexible and reliable, even with built-in LISN, allow you to perform conducted and radiated test in full compliance CISPR 16-1-1 and MIL-STD

 


PMM  FR4003 - Full compliance field receiver 9 kHz - 30 MHzTop of page PMM

The FR4003 is a new reference in measuring electric fields up to 30 MHz. Thanks to its innovative approach it fully meets all MIL-STD andCISPR specifications of the rod antennas and it is, at the same time, a real full compliant CISPR 16-1-1 EMI receiver.

It can be used in stand alone mode, connected to a PC or connected to a Narda-PMM receiver. Nonetheless, it can maintain full legacy with any standard receiver, because it also has the traditional coaxial cable output. 

An internal tracking generator allows performing a self-calibration procedure which always guarantees optimum performances, ensuring the accuracy of measurements.

The same internal tracking generator is part of an internal capacitance meter that becomes essential not only for the self-calibration, but also for verifying the grounding effectiveness of the antenna.

Thanks to its replaceable Li-Ion battery, the FR4003 can work for several hours with no connection having thus unperturbed field.

 

 

 

 

The field receiver FR-4003 is fully compliant to:

  • CISPR 12
  • CISPR 16
  • CISPR 25
  • MIL-STD
  • DO-160

Product description PDF format : English


 

PMM  7010 - Pre compliance receiver 9 kHz - 3 Ghz with built-in LISN Top of pagePMM

PMM 7000

The 7010 is a very flexible EMI receiver, suitable for radiated measurements from 9 kHz to 3 GHz. Thanks to its internal LISN, the 7010 allows you to conduct comprehensive emission measurements and characterization of EUT without any external or additional equipment. The compact and robust design makes the 7010 a perfect companion for the workbench, for on-site testing and for laboratories carrying out pre-qualification measurements for EMI emissions.

Built according to CISPR 16-1-1 and 16-1-2

Available into 4 different versions:

  • 7010/00 – da 150 kHz a 1 GHz
  • 7010/01 – da 9 kHz a 1 GHz
  • 7010/02 – da 9 kHz a 30 MHz
  • 7010/03 – da 9 kHz a 3 GHz

Product description PDF formatEnglish

 


PMM  9010 - Full compliance receiver 10Hz - 30 MHzTop of page PMM

 PMM 9010 The 9010 is a fully compliant EMI Receiver CISPR 16-1-1.

The 9010 is also equipped with all the filters and the detectors in full accordance with CISPR, MIL-STD standards, APD function and Click measures.

The 9010 is provided with a preamplifier, a pulse limiter and an internal tracking generator. It has the functions of sweep, spectrum analyzer, scalar network analyzer and manual receiver.

The frequency range of 9010 can be expanded up to 18 GHz thanks to the use of external units 9030, 9060 and 9180.

Product description PDF format : English



PMM  9010F - FFT full compliance receiver 10 Hz - 30 MHzTop of page PMM

The 9010F is an EMI receiver based on an analog-digital conversion and an advanced data processing using the FFT spectrum frequency analysis in full compliance with all the tests required in CISPR 16-1- 1.

The FFT technology allows for real-time data, this excludes the loss of data within the analyzed band.

The 9010F is also equipped with all the filters and the detectors in full accordance with the law with the CISPR and MIL-STD standards.

The frequency range of the 9010F can be expanded up to 18 GHz thanks to the use of external units 9030, 9060 and 9180.

      •  
 
Watch the video on the difference in measurement speed bettween 9010F and 9010

Product description PDF format : English


PMM  Serie 9010/XXP - Full/Pre compliance receivers 10 Hz- 6 GHzTop of page PMM

 PMM 9010

Narda-PMM has developed new EMI / EMC receivers based on an innovative concept and a revolutionary approach to meet the needs of small and medium-sized laboratories that do not find it convenient to invest in a receiver conforming to the CISPR 16-1-1 also for radiated measurements.

They are a perfect mix of full and Pre-Compliance to meet, in a perfect way, the requirements of practical tests, not excluding the possibility of future upgrades to 100% Full-Compliant to CISPR 16-1-1 up to 3, 6 or 18 GHz the simple addition of an external unit, 9030, 9060 or 9180, connected via fiber optic cable.

The 9010 / xxP series receivers, are full compliance in accordance with the CISPR 16-1-1 in the band A and B and pre compliance in the next

Receivers 9010/xxp are available in the following versions:

  • 9010/03P, 10 Hz – 300 MHz
  • 9010/30P, 10 Hz – 3 GHz
  • 9010/60P, 10 Hz – 6 GHz

Product description PDF formatEnglish


PMM  9030, 9060 , 9180 - External units full compliance 30 MHz - 18 GHzTop of pagePMM

PMM 7000With the external units 9030, 9060 and 9180 you can easily extend the frequency range of your receiver up to a maximum of 18 GHz.

Light and compact size, these units are equipped with a rechargeable Lio-on that allows you to work for hours without any interference.

These external units are fully compliant with CISPR16-1-1 requirements and meet all commercial and military standards for EMC measurements. All external units are fully compatible with the receivers of the 9010 Series, 9010 and 9010F / xxP

The 3 available models are:

  • 9030 – da 30MHz a 3 GHZ
  • 9060 – da 30 MHz a 6 GHZ
  • 9180 – da 6 a 18 GHZ

 

Product description PDF formatEnglish


 