5
|
|
| |
 Conducted Emission
9010/30P  |
| |
PMM 9010/30P EMI Measuring Receiver & Analyzer 10 Hz - 3 GHz.
NARDA-PMM innovative concept in EMC Testing has generated a new EMC/EMI Receiver with a revolutionary approach to the most felt requirements by medium and small size laboratories which don’t feel very comfortable investing in a CISPR 16-1-1 Full-Compliant Receiver for Radiated Frequency Range too.
In practice, to perform truly Full Compliant Radiated Emission Tests, an appropriate test site should be made available for hosting both EUT (Equipment Under Test) and Receiving Antenna separated by 3, 10 or even 30 meters distance, like SAC (Semi-Anechoic Chambers) or OATS (Open Area Test Sites), this usually means an huge investment in terms of RF shielding and absorbing materials.
Nevertheless, with appropriate methodology and care to discriminate as much as possible noise contributions coming from the environment vs. those generated by the EUT, it’s also possible to perform good evaluative radiated emission tests in an Open Space with a Pre-Compliant Receiver and this is exactly the purpose 9010/30P has been designed for in the range 30 - 3000 MHz. On the other side, looking to Conducted Emissions Tests requirements, Full Compliance toward each specific Product Standard can be easily fulfilled with a significantly lower budget investment, i.e. no specific environment is required but only few components (EMI Receiver, LISN or High Voltage Probe, etc.), and that’s why having a Full Compliant Receiver for the range 9 kHz - 30 MHz becomes really convenient just comparing its cost to that of tests performed in a 3rd party laboratory.
In few words, with PMM 9010/30P the mix of Full and Pre-Compliant features provides a perfect match to practical testing requirements, not excluding the possibility of future upgrades to 100% CISPR 16-1-1 Full-Compliance up to 3 or 6 GHz or 18 GHz with simple addition of PMM 9030 or PMM 9060 or PMM 9180 extension units digitally connected through fiber optic cable. All other features provided by previously released PMM 9010 Full-Compliant Receiver remains unchanged in 9010/30P too, including optional Click Analyzer Function and MIL-STD 461 Filters.
The already widely appreciated software “PMM Emission Suite” can properly control 9010/30P as well.
Product description and specifications : 
|
PMM Emission Suite Software  |
 |
PMM 9010/9030/9060 Emission Suite PC Software.
A powerful Software Utility that add PMM 9010, PMM 9030 and PMM 9060 receivers of extremely useful functions to control measurements as well as to collect, analyze and post-process data safely and easily as never before.
Read more details...>
Product description : 
|
LISNs Line Impedance Stabilization Networks  |
|
|
Suitable from small to very large currents, the PMM Line Impedance Stabilization Networks are the state-of-art complement for full CISPR compliant measurements.
Can be controlled by PMM receivers and software to build automatic test systems.
L1-150M (Multi-standard Single-path, 150A)
L2-16B (Single phase and DC powered EUTs, 16A)
L3-32 (3-phase, 32A)
L3-64 (3-phase, 63A)
L3-100 (3-phase, 100A)
|
L1-150M Multi-standard Single-path LISN (Line Impedance Stabilization Network)  |
|
MAIN FEATURES 
- Multi-standard design
- 0.1 to 200 MHz frequency range
- 150 A max output current
- Large baseplate for optimal grounding
- Robust, compact construction
- Screw terminals for safe wiring
PMM L1-150M is a single-path LISN (Line Impedance Stabilization Network) designed to
be easily used for conducted disturbances measurements according to different
standards for Automotive and ISM (Industrial, Scientific, Medical) applications:
CISPR 16-1-2
CISPR 25 / ISO 11452-4
ISO 7637-2
Selecting the standard is as fast as the turn of a rotary switch located on the rear panel.
It can be used in conjunction with any EMI Receiver or Spectrum Analyzer.
Product description : 
|
SHC Voltage Probes  |
 |
A wide range of accessories such as: Antennas, High Voltage Probes, Absorbing Clamps, Near Field Probes, etc. and other complete the range of products. This will enable the operator to always have the correct set-up for any EMC standard. Several accessories enlarge the capability of the systems in any test condition to offer a useful tool either to achieve the CE mark or for design debugging and pre-qualification testing. |
|
|